 FUJITSU SEMICONDUCTOR DATA SHEET
DS05-20885-1E
FLASH MEMORY
CMOS
128 M (16 M x 8) BIT NAND-type
MBM30LV0128
s DESCRIPTION
The MBM30LV0128 device is a single 3.3 V 16 M x 8 bit NAND flash memory organized as 528 byte x 32 pages x 1024 blocks. Each 528 byte page contains 16 bytes of optionally selected spare area which may be used to store ECC code (Specifications indicated are on condition that ECC system would be combined) . Program and read data is transferred between the memory array and page register in 528 byte increments. A 528 byte page can be programmed in 200 s and an 16 K byte block can be erased in 2 ms under typical conditions. An internal controller automates all programs and erases operations including the verification of data margins. Data within a page can be read with a 50 ns cycle time per byte. The I/O pins are utilized for both address and data input/output as well as command inputs. The MBM30LV0128 is an ideal solution for applications requiring mass non-volatile storage such as solid state file storage, digital recording, image file memory for still cameras, and other uses which require high density and non-volatile storage.
s PRODUCT LINE UP
Part No. Operating Temperature VCC Read Power Dissipation (Max.) Erase / Program TTL Standby CMOS Standby MBM30LV0128 -40 C to +85 C +2.7 V to +3.6 V 72 mW 72 mW 3.6 mW 0.18 mW
MBM30LV0128
s FEATURES
* 3.3 V-only operating voltage (2.7 V to 3.6 V) Minimizes system level power requirements * Organization Memory Cell Array : (16 M + 512 K) x 8 bit Data Register : (512 + 16) x 8 bit * Automatic Program and Erase Page Program : (512 + 16) Byte Block Erase : (16 K + 512) Byte * 528 Byte Page Read Operation Random Access : 10 s (Max.) Serial Access : 35 ns (Max.) * Fast Program and Erase Program Time : 200 s (Typ.) / page Block Erase Time : 2 ms (Typ.) / block * Command/Address/Data Multiplexed I/O Port * Hardware Data Protection * 1,000,000 write/erase cycles guaranteed (ECC system required) * Command Register Operation * Package 48-pin TSOP Type I (0.5 mm pitch) Normal/Reverse Type * Data Retention : 10 years
s PACKAGES
48-pin plastic TSOP (II)
(FPT-48P-M19) (Normal Bend)
(FPT-48P-M20) (Reverse Bend)
2
MBM30LV0128
s PIN ASSIGNMENTS
TSOP (I)
N.C. N.C. N.C. N.C. N.C. SE R/B RE CE N.C. N.C. VCC VSS N.C. N.C. CLE ALE WE WP N.C. N.C. N.C. N.C. N.C. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 (Marking Side) 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 N.C. N.C. N.C. N.C. I/O7 I/O6 I/O5 I/O4 N.C. N.C. N.C. VCCq VSS N.C. N.C. N.C. I/O3 I/O2 I/O1 I/O0 N.C. N.C. N.C. N.C.
Standard Pinout
FPT-48P-M19
N.C. N.C. N.C. N.C. N.C. WP WE ALE CLE N.C. N.C. VSS VCC N.C. N.C. CE RE R/B SE N.C. N.C. N.C. N.C. N.C.
24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
(Marking Side)
Reverse Pinout
25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48
N.C. N.C. N.C. N.C. I/O0 I/O1 I/O2 I/O3 N.C. N.C. N.C. VSS VCCq N.C. N.C. N.C. I/O4 I/O5 I/O6 I/O7 N.C. N.C. N.C. N.C.
FPT-48P-M20
3
MBM30LV0128
s PIN FUNCTIONS
PIN Number 29 to 32 41 to 44 Pin Name Pin Functions Data Input/Output : The I/O ports are used for transferring command, address, and input/output data into and out of the device. The I/O pins will be high impedance when the outputs are disabled or the device is not selected. Command Latch Enable : The CLE signal enables the acquisition of the mode command into the internal command register. When CLE = "H", command is latched into the command register from the I/O port upon the rising edge of the WE signal. Address Latch Enable : The ALE signal enables the acquisition of either addresses or data into the internal address/data register. The rising edge of WE will latch in addresses when ALE is high and data when ALE is low. Chip Enable : The CE signal is used to select the device. When CE is high, the device enters a low power standby mode. If CE transitions are high during a read operation, the standby mode will be entered. However, the CE signal is ignored if the device is in a busy state (R/B = "L") during a program or erase operation. Read Enable : The RE signal controls the serial data output. The falling edge of RE drives the data onto the I/O bus and increments the column address counter by one. Write Enable : The WE signal controls write from the I/O port. Data, address, and commands on the I/O port are latched upon the rising edge of the WE pulse. Write Protect : The WP signal protects the device against accidental erasure or programming during power up/down by disabling the internal high voltage generators. WP should be kept low when the device powers up until Vcc is above 2.5 V. During power down, WP should be low when Vcc falls below 2.5 V. Spare Area Enable : The SE input enables the spare area during sequential data input, page program, and Read 1. Ready Busy Output : The R/B output signal is used to indicate the operating status of the device. During program, erase, or read, R/B is low and will return high upon the completion of the operation. The output buffer for this signal is an open drain. Output Buffer Power Supply : The VCCq input supplies the power to the I/O interface logic. This power line is electrically isolated from VCC for the purpose of supporting 5 V tolerant I/O.
I/O0 to I/O7
16
CLE
17
ALE
9
CE
8
RE
18
WE
19
WP
6
SE
7
R/B
37
VCCq
(Continued)
4
MBM30LV0128
(Continued) PIN Number
12 13, 36 1 to 5 10, 11 14, 15 20 to 24 25 to 28 33 to 35 38 to 40 45 to 48
Pin Name VCC VSS Power Supply Ground
Pin Functions
N.C.
Non Connection
5
MBM30LV0128
s BLOCK DIAGRAM
R/B High Voltage Pumps ALE CLE SE WP CE RE WE Y-Decoder Data Register & S/A State Machine X Decoder
Memory Array
Command Register
Data Register & S/A Y-Decoder
Address Register
Status Register I/O Register & Buffer I/O0 to I/O7
VCC VCCq VSS
6
MBM30LV0128
s SCHEMATIC CELL LAYOUT AND ADDRESS ASSIGNMENT
The Program operation is implemented in page units while the Erase operation is carried out in block units.
I/O0 Register 512 16 I/O7
Read and Program operations are executed through Register Register = 1 page size
32 pages 1 block
Memory Cell Array
32768 pages (1024 blocks)
8 I/O
528
1) A page consists of (512 + 16) bytes; - 512 bytes for main memory - 16 bytes for redundancy or other use 2) A block consists of 16 pages; (16 K + 512) bytes. 3) Total device density = 528 bytes x 32 pages x 1024 blocks.
Figure 1 Schematic Cell Layout
Table 1 I/O0 First Cycle Second Cycle Third Cycle A0 A9 A17 I/O1 A1 A10 A18 I/O2 A2 A11 A19
Addressing I/O3 A3 A12 A20 I/O4 A4 A13 A21 I/O5 A5 A14 A22 I/O6 A6 A15 A23 I/O7 A7 A16 X*
A0 to A7 : column address A9 to A23 : page address A14 to A23 : block address A9 to A13 : Page address in block
(A8 is automatically set to "Low" or "High" by the "00h" command or the "01h" command inside the device.) * : X = VIH or VIL
7
MBM30LV0128
s DEVICE BUS OPERATIONS
Table 2 Operation Table *1 Mode Read Mode Command Input Address Input (3 clocks) CLE H L L L H L L X X X X ALE L H L L L H L X X X X CE L L L L L L L X X X H X X X X H H H H H X X X X WE RE H H H SE X *4 X *4 L/H *3 L/H * X*
4 3
WP X X X X H H H H H L
During Read (Busy) Sequential Read & Data Output Program/ Command Input Erase Address Input (2 or 3 clocks) Mode Data Input During Program (Busy) During Erase (Busy) Write Protect Stand-by *1: H : VIH, L : VIL, X : VIH or VIL
X *4 L/H *3 L/H *3 X X
0 V/VCC*2 0 V/VCC*2
*2: WP should be biased to CMOS high or CMOS low for standby. *3: When SE is high, spare area is deselected. *4: If 50h command is input and read/program operation is executed only for spare area, SE must be low at the command/address input. Table 3 Operation Output Select Output Deselect Standby CLE L L X ALE L L X Read Mode Operation Status * CE L L H WE H H X RE L H X I/O0 to I/O7 Data Output High Impedance High Impedance Power Supply Active Active Standby
*: H : VIH, L : VIL, X : VIH or VIL
8
MBM30LV0128
s COMMAND OPERATION
Table 4 Command Table Function Read (1) Read (2) Read (3) Sequential Data Input Sequential Data Imput for Double Page Program Page Program Block Erase Reset Status Read ID Read 1st Cycle 00h *1 01h *2 50h *3 80h 82h 10h 60h FFh 70h 90h 2nd Cycle D0h Acceptable Command During Busy State
*1: The 00h Command defines starting Address on the 1st half of the Page. *2: The 01h Command defines starting Address on the 2nd half of the Page. *3: The 50h Command is valid only When SE is low level.
9
MBM30LV0128
s FUNCTIONAL DESCRIPTION
READ MODE There are three distinct commands used for the read operation : 00h, 01h, and 50h. After the command cycle, three address cycles are used to input the starting address. Upon the rising edge of the final WE pulse, there is a 10 s latency in which the 528 byte page is transferred to the data register. The R/B signal may be used to monitor the completion of the data transfer. Once the data page has been loaded into the data register, it may be clocked out with consecutive 50 ns RE pulses. Each RE pulse will automatically advance the column address by one. Once the last column has been read, the page address will automatically increment by one and the data register will be updated with the new page after 10 s. In this sequential read operation, the CE signal must stay "Low" after the third address input and during Busy state. If the CE signal goes High during this period, the read operation will be terminated and then the standby mode will be entered. (In the read operation, after read command and address input, the CE signal can be "Don't care" after the third address input and during Busy state.) The 00h Read command will set the pointer to the first half of the page of the array while the 01h Read command sets it in the second half. It may be logical to think of 00h as a command which sets A8 = 0 while 01h sets A8 = 1. The 50h command sets the pointer to the spare area, consisting of columns 512 to 527. During this read mode, A3 to A0 is used to set the starting address of the spare area. As with the 00h and 01h operations, once the spare area page is loaded into the data register, it may be read out by RE pulses. Each RE pulse will increment the column address until the final column (527) is reached. At this time, the pointer will be reset to column 512 while the page address is incriminated and the data register is updated. (In this sequential read operation also, CE signal must stay "Low" after the third address input and during Busy state.) The 00h or 01h command is required to move the pointer back into the main array area. Read (1) , (2) : 00h/01h The Read (1) , (2) mode is invoked by latching the 00h or 01h command into the command register. This mode (00h) will automatically be selected when the device powers up.
CE
CLE ALE WE RE R/B I/O0 to I/O7
Command 01h 00h 0 255 511 527
Starting Address Y X X
Data Output
Page (Row) Address
X
Y Y (Column Address)
Figure 2 Read Mode (1) , (2) Operation 10
MBM30LV0128
Read (3) : 50h The Read (3) mode has identical timing to that of Read (1) and (2) . However, while Read (1) and (2) are used to access the array, Read (3) is used to access the 16 byte spare area. When the 50h command is executed, the pointer will be set to an address space between columns 512 and 527. The values of Y will complete the address decoding. During this operation, only address bits A3 to A0 are used to determine the starting column address; A7 to A4 are ignored. A23 to A9 are used to determine the starting row address.
CE CLE ALE WE RE R/B
Starting Address Data Output
I/O0 to I/O7
Y Command 50h 0 Page (Row) Address X
X
X
255
511 527
Y (Column Address)
Figure 3 Read Mode (3) Operation
Sequential Read Each RE pulse used to output data from the data register will cause the column address pointer to increment by one. When the final column has been reached, the next page will be automatically loaded into the data register. The R/B signal may be used to monitor the completion of the data transfer.
R/B I/O0 to I/O7
00h/01h/50h 0 255 Address Input 255 Data 511 527 0 Data 255 511 527 0 Data 255 511 527
511 527 0
00h, SE = L
01h, SE = L
00h, SE = H
50h, SE = L
Figure 4
Sequential Read
11
MBM30LV0128
Page Program : 80h, 10h The device is programmed either by the page or partial page. Programming is done by issuing the 80h command followed by three address cycles then serial data input. The 80h command may be preceded by either 00h, 01h or 50h to set the pointer to either the first half page, second half page, or spare area respectively. If the pointer command is not specifically issued, its location is determined by its previous use (see Application Note (2) ) . After the serial data input, any column address which did not receive new data will not be programmed. This enables a page to be partially programmed. After the data has been entered, the 10h command will initiate the embedded programming process. If the 10h command is issued without loading any new data, programming will not be initiated. A given page may not be partially programmed more than five consecutive times without an intervening erase operation. During the programming cycle, the R/B pin or Status Register bit I/O6 may be used to monitor the completion of the programming cycle. Only the Reset and Read Status commands are valid while programming is in progress. After programming, the Status Register bit I/O0 should be checked to verify whether the procedure was successful or not.
R/B
I/O0 to I/O7
80h
Address and Data Input
10h
70h
I/O0 0 = Pass 1 = Fail
Figure 5 Page Program
Double Page Progam : 82h, 10h The device has a double page program function to program two consecutive pages of data in 2 Flash pages. The page must firstly be in the order of even page data (528 Bytes) followed by "odd page data" secondly (528 Bytes) .The 82h command may be preceded by 00h, 01h or 50h to set the pointer to the first half of even page, or to the second half of even page or to the spare area of even page respectively. If the pointer command is not specifically issued, its location is determined by its previous use. Other use or operations are the same as Page Program operations which use 80h command. (Partial Program, to input 10h command, R/B, Status register.) Block Erase : 60h, D0h The device data is erased in a block consisting of sixteen pages. The erase operation begins with the 60h command followed by two address cycles in which the block to be erased is entered. While the two address cycles require A23 to A9 to be entered, A13 to A9 are "don't care" bits. Once the block address is successfully loaded, the D0h command is entered to initiate the erase operation. The R/B signal may be used to monitor the completion of the cycle. Upon completion, the Status Register bit I/O0 should be used to verify a successful erase.
R/B
I/O0 to I/O7
60h
Address Input
D0h
70h
I/O0 0 = Pass 1 = Fail
Figure 6 Block Erase
12
MBM30LV0128
Read ID : 90h This mode allows the identification of the manufacturer and product. After the 90h command cycle, one address cycle follows in which 00h is entered. The next two RE pulses will output the manufacturer and device codes respectively.
RE
I/O0 to I/O7
90h
00h
04h Manufacturer Code
73h Device Code
Figure 7
Read ID Operation
Table 5 Code Table I/O7 Manufacturer Device 0 0 I/O6 0 1 I/O5 0 1 I/O4 0 1 I/O3 0 0 I/O2 1 0 I/O1 0 1 I/O0 0 1 Code 04h 73h
Status Read : 70h The Status Register may be used to determine if the device is ready, in the write protect mode, or passed program/erase operations. After the 70h command is entered, the more recent falling edge of either CE or RE will output the contents of the status register to I/O0 to 7. The status register is continually updated and does not require either CE or RE to be toggled. By utilizing the CE pin, multiple devices with R/B pins wired together may be polled to determine their specific status. Table 6 Status Output Table Status I/O0 I/O1 I/O2 I/O3 I/O4 I/O5 I/O6 I/O7 Program/Erase Not Used Not Used Not Used Not Used Not Used Ready/Busy Write Protect 0 = Busy; 1 = Ready 0 = Protected; 1 = Unprotected Description 0 = Pass; 1 = Fail
13
MBM30LV0128
CE (1) ALE CLE WE RE Device (1)
CE (2)
CE (N)
Device (2)
Device (N)
8 I/O0 to I/O7 R/B
R/B
ALE CLE WE CE (1) CE (N) RE I/O0 to I/O7
70h 0/1 Status of Device (1) 70h 0/1 Status of Device (N)
Figure 8 Status Read
Reset When the device is busy during program, erase, or read, it can be reset by entering the command FFh. If WP equals 1, the Status Register will be set to C0h. If a reset command is issued while the device is in the reset state, the command will be ignored. If the device is reset during the program or erase operations, the internal high voltages will be discharged before R/B goes high.
R/B I/O0 to I/O7
FFh
14
MBM30LV0128
s ABSOLUTE MAXIMUM RATINGS
Parameter Ambient Temperature with Power Applied Storage Temperature Voltage on an I/O pin with Respect to Ground (Note) Voltage on a pin Except I/O with Respect to Ground (Note) Power Supply Voltage Symbol Ta Tstg VI/O VIN VCC VCCq Rating Min. -40 -55 -0.6 -0.6 -0.6 -0.6 Max. +85 +125 VCCq + 0.5 VCC + 0.5 +5.5 +6.0 Unit C C V V V
Note: Minimum DC voltage on input or I/O pins are -0.5 V. During voltage transtions, inputs may undershoot VSS to -2.0 V for periods of up to 20 ns. Maximum DC voltage on input pins are VCC + 0.5 V and on I/O pins are VCCq + 0.5 V. During voltage transitions, input pins may overshoot to VCC + 2.0 V for periods of up to 20 ns and I/O pins may overshoot to VCCq + 2.0 V for periods of up to 20 ns. WARNING: Semiconductor devices can be permanently damaged by application of stress (voltage, current, temperature, etc.) in excess of absolute maximum ratings. Do not exceed these ratings.
s RECOMMENDED OPERATING CONDITIONS
Parameter Supply Voltages Supply Voltages Voltages Ambient Temperature Symbol VCC VCCq (Note) VSS Ta -40 Value Min. +2.7 +2.7 0 +85 Max. +3.6 +5.5 Unit V V V C
Note : VCCq = 5.0 V 10% can be guaranteed on VCC 3.0 V Operating ranges define those limits between which the functionality of the device is guaranteed. WARNING: The recommended operating conditions are required in order to ensure the normal operation of the semiconductor device. All of the device's electrical characteristics are warranted when the device is operated within these ranges. Always use semiconductor devices within their recommended operating condition ranges. Operation outside these ranges may adversely affect reliability and could result in device failure. No warranty is made with respect to uses, operating conditions, or combinations not represented on the data sheet. Users considering application outside the listed conditions are advised to contact their FUJITSU representatives beforehand.
15
MBM30LV0128
s ELECTRICAL CHARACTERISTICS
1. DC Characteristics
Parameter Sequential Read Current Command Address Input Current Data Input Current Program Current Erase Current Stand-by Current (TTL) Stand-by Current (CMOS) Input Leakage Current Output Leakage Current Input High Voltage Input Low Voltage Output High Voltage Level Output Low Voltage Level Output Low Current (R/B) Symbol ICC1 ICC3 ICC4 ICC6 ICC7 ISB1 ISB2 ILI ILO VIH VIL VOH VOL IOL Conditions tCYCLE = 50 ns, CE = VIL, IOUT = 0 mA tCYCLE = 50 ns, CE = VIL CE = VIH, WP = SE = 0 V/VCC CE = VCC - 0.2 V, WP = SE = 0 V/ VCC VIN = 0 to 3.6 V VOUT = 0 to 3.6 V I/O pins Except I/O pins IOH = -400 A IOL = 2.1 mA VOL = 0.4 V Value Min. 2.0 2.0 -0.3 2.4 8 Typ. 10 10 10 10 10 10 10 Max. 20 20 20 20 20 1 50 10 10 VCCq + 0.3 VCC + 0.3 0.8 0.4 Unit mA mA mA mA mA mA A A A V V V V V mA
16
MBM30LV0128
2. AC Characteristics (Note 1)
Parameter CLE Setup Time CLE Hold Time CE Setup Time CE Hold Time Write Pulse Width ALE Setup Time ALE Hold Time Data Setup Time Data Hold Time Write Cycle Time WE High Hold Time WP High to WE Low Ready to RE Falling Edge Read Pulse Width Read Cycle Time RE Access Time (Serial Data Access) CE High Time for the Last Address in Serial Read Cycle (Note 3) RE Access Time (ID Read) RE High to Output High Impedance CE High to Output High Impedance RE High Hold Time Output High Impedance to RE Falling Edge RE Access Time (Status Read) CE Access Time (Status Read) WE High to RE Low ALE Low to RE Low (ID Read) CE Low to RE Low (ID Read) Data Transfer from Memory Cell Array to Register WE High to Busy ALE Low to RE Low (Read Cycle) Symbol tCLS tCLH tCS tCH tWP tALS tALH tDS tDH tWC tWH tWW tRR tRP tRC tREA tCEH tREAID tRHZ tCHZ tREH tIR tRSTO tCSTO tWHR tAR1 tCR tR tWB tAR2 Value Min. 0 10 0 10 25 0 10 20 10 50 15 100 20 30 50 100 15 15 0 60 100 100 50 Max. 35 35 30 20 35 45 7 100 Unit ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns ns s ns ns
(Continued)
17
MBM30LV0128
(Continued)
Parameter RE Last Clock Rising Edge to Busy (in Sequential Read) CE High to Ready (in Case of Interception by CE in Read Mode) (Note 2) Device Resetting Time (Read/Program/Erase) Notes : 1. AC Test Conditions : Operating range Input level Input comparison level Output data comparison level Output load Load capacitance (CL) Transition time (tT) 50 pF 5 ns VCC = 2.7 to 3.6 V VCC = 3.0 to 3.6 V 2.4 V/0.4 V 1.5 V/1.5 V 1.5 V/1.5 V 1TTL 100 pF Symbol tRB tCRY tRST Value Min. Max. 100 50 + tr (R/B) 5/10/500 Unit ns ns s
2. The time to go from CE high to Ready depends on the pull-up resister of the R/B pin (see Application Notes (6) ) toward the end of this document. 3. If you toggle CE to high after access to the last address (address 527) in the resister in the read mode (1) , (2) , and (3) , the CE high time must be held for 100 ns or more when the delay time of CE with respect to RE is 0 to 200 ns (see the figure below) . When the CE delay time is within 30 ns, the device is kept in the Ready state and will output no Busy signal.
tCEH 100 ns
*
CE RE
A 525 509 526 510 527 511
*: VIH or VIL
A : 0 to 30 ns Busy signal is not output.
R/B
Busy
18
MBM30LV0128
s ERASE AND PROGRAMMING PERFORMANCE
Parameter Average Programming Time Number of Programming Cycles on Same Page Block Erasing Time Number of Program/Erase Cycles Symbol tPROG N tBERASE P/E Value Min. 1 x 106 Typ. 200 2 Max. 1000 5 10 ms 2 Unit s 1 Note
Notes: 1. Refer to Application Note (10) toward the end of this document. 2. This specification is on conditions that ECC systems would be combined. Refer to Application Note (13) toward the end of this document.
s VALID BLOCKS
The MBM30LV0128 occasionally contains unusable blocks. Refer to Application Note (12) toward the end of this document. Value Parameter Symbol Unit Min. Typ. Max. Valid Block Number NVB 1014 1020 1024 Block
s PIN CAPACITANCE
Parameter Input Capacitance Output Capacitance Symbol CIN COUT VIN = 0 VOUT = 0 Condition Value Typ. Max. 10 10 Unit pF pF
Notes : 1. Test conditions Ta = 25 C, f = 1.0 MHz 2. Sampled, not 100% tested.
19
MBM30LV0128
s TIMING DIAGRAMS
CLE
tCLH tCH
tCLS tCS
CE
tWP
WE
tALS tALH
ALE
tDS tDH
I/O0 to I/O7
: VIH or VIL
Figure 9 Command Input Cycle Timing Diagram
tCLS
CLE
tCS tWC tWC
CE
tWP tWH tWP tWH tWP
WE
tALS tALH
ALE
tDS tDH tDS tDH tDS tDH
I/O0 to I/O7
A0 to A7
A9 to A16
A17 to A23 : VIH or VIL
Figure 10
Address Input Cycle Timing Diagram
20
MBM30LV0128
tCLH
CLE
tCH
CE
tALS tWC
ALE
tWP tWH tWP tWP
WE
tDS tDH tDS tDH tDS DIN * tDH
I/O0 to I/O7
* : SE = GND input : to DIN 527 = VCC input : to DIN 511
DINN
DINN + 1
: VIH or VIL
Figure 11 Data Input Cycle Timing Diagram
21
MBM30LV0128
tRC
CE
tRP tREH tRP tRP tCHZ tREA tRHZ tREA tREA tRHZ tRHZ
RE
I/O0 to I/O7
tRR
R/B
Figure 12
Serial Read Cycle Timing Diagram
tCLS
CLE
tCLS tCLH tCS
CE
tWP
tCH
tCSTO tCHZ tWHR
WE
RE
tDS tDH
tIR tRHZ tRSTO Status Output
I/O0 to I/O7
70h
R/B
: VIH or VIL
Figure 13 Status Read Cycle Timing Diagram
22
MBM30LV0128
CLE
tCLS tCLH tCH tWC tALS tALH tR tCRY tAR2 tCEH
CE
tCS
WE ALE
tALH tWB tDS tDS tDS tRR tRC
RE I/O0 to I/O7
tDS
tDH
tDH
tDH
tDH
tREA DOUT N DOUT N+1 DOUT N+2
00h
A0 to A9 to A7 A16 Column address N
A17 to A23
** DOUT tRB
R/B
** : SE = GND input : DOUT 527 = VCC input : DOUT 511 : VIH or VIL
Figure 14 Read Cycle (1) Timing Diagram
CLE CE
tCLS
tCLH tCH tWC tR tALS tALH tWB tALH tAR2 tCHZ
tCS
WE ALE
tRR
tRC tRHZ
RE I/O0 to I/O7
tDS tDH 00h
tDS tDH
tDS tDH
tDS tDH A17 to A23 tREA DOUT N DOUT N+1 DOUT N+2
A0 to A9 to A7 A16 Column address N ***
R/B
*** : Read Operation using 00h Command Read Operation using 01h Command N : 0 to 255 N : 256 to 511 : VIH or VIL
Figure 15
Read Cycle (1) Timing Diagram : Interrupted by CE
23
MBM30LV0128
CLE
tCLS tCS
tCLH tCH
CE
WE
tALS tWB
tR tALH tALH
tAR2
ALE
tRC
RE
tDS tDH tDS tDH tRR A0 to A7 A9 to A16 A17 to A23 DOUT 256 + M tREA DOUT 256 + M + 1 ** DOUT
I/O0 to I/O7
01h
Column address M
R/B
** : SE = GND input : DOUT 527 = VCC input : DOUT 511 : VIH or VIL
Figure 16 Read Cycle (2) Timing Diagram
CLE
tCLS tCS
tCLH tCH
CE
WE
tALS tWB
tR tALH tALH
tAR2
ALE
tRC
RE
tDS tDH tDS tDH tRR A0 to A7 A9 to A16 A17 to A23 DOUT 512 + M tREA DOUT 512 + M + 1
I/O0 to I/O7
50h
** DOUT 527
Column address M
R/B
** : SE = GND input : DOUT 527 = Do not input VCC : VIH or VIL
Figure 17 Read Cycle (3) Timing Diagram
24
MBM30LV0128
CLE CE
WE ALE RE I/O0 to I/O7
00h A0 to A9 to A17 to A7 A16 A23 Column Page Address Address M N tR N
N+1 N+2
**
0
1
2
**
tR
R/B
Page M Access ** : SE = GND input : DOUT 527 = VCC input : DOUT 511 : VIH or VIL
Note : The CE can be "H or L" after the third address input and during busy state. But, for the sequential read operation, CE must stay "L" after RE toggling for final column address data read and during busy state. Figure 18 Sequential Read (1) Timing Diagram
CLE CE
WE ALE RE I/O0 to I/O7
01h A0 to A9 to A17 to A7 A16 A23 Column Page Address Address M N tR 256 256 256 + + + N N+1 N+2 ** 0 1 2 **
tR
R/B
Page M Access ** : SE = GND input : DOUT 527 = VCC input : DOUT 511 Page M + 1 Access : VIH or VIL
Note : The CE can be "H or L" after the third address input and during busy state. But, for the sequential read operation, CE must stay "L" after RE toggling for final column address data read and during busy state. Figure 19 Sequential Read (2) Timing Diagram 25
MBM30LV0128
CLE CE
WE ALE RE I/O0 to I/O7
50h A0 to A9 to A17 to A7 A16 A23 tR Column Page Address Address M N 512 512 512 + + + N N+1 N+2 ** 512 513 514 **
tR
R/B
Page M Access ** : SE = GND input : DOUT 527 = Do not input VCC
Page M + 1 Access : VIH or VIL
Note : The CE can be "H or L" after the third address input and during busy state. But, for the sequential read operation, CE must stay "L" after RE toggling for final column address data read and during busy state. Figure 20 Sequential Read Cycle (3) Timing Diagram
26
MBM30LV0128
CLE
tCLS tCLS tCLS tCS tCS tCH
CE WE
tALS tALH tALH
tALS
tPROG tWB
ALE
RE
tDS
tDH
tDS
tDH A0 to A7 A9 to A16 A17 to A23
tDH tDS DIN N
N+1
tDH tDS DIN DIN * 10h 70h
Status Output
I/O0 to I/O7 R/B
80h**
* : SE = GND input : to DIN 527 (to DIN 527 of odd page for double page program) = VCC input : to DIN 511 (to DIN 511 of odd page for double page program) ** : 82h for double page program
: VIH or VIL
Figure 21
Auto Program Operation Timing Diagram
CLE
tCLS tCLH tCLS
CE
tCS
WE
tALH tALS tBERASE tWB
ALE
RE I/O0 to I/O7 R/B
tDS tDH 60h A9 to A16 A17 to A23 D0h 70h
Status Output
Auto Block Erase Setup Command
Erase Start Command
Status Read Command : VIH or VIL
Figure 22 Auto Block Erase Timing Diagram
27
MBM30LV0128
CLE
tCS
tCLS tCH tCLS
CE
tCS tALH tCH tCR tAR1
WE
tALH
tALS
ALE RE I/O0 to I/O7
tDS tDH 90h 00h tREAID Address Input Maker Code 04h tREAID Device Code : VIH or VIL 73h
Figure 23 ID Read Operation Timing Diagram
28
MBM30LV0128
s APPLICATION NOTES AND COMMENTS
(1) Prohibition of unspecified commands The operation commands are listed in Table 4. Data input as a command in other than the specified commands in Table 4 are prohibited. Stored data may be corrupted if an unspecified command is entered during the command cycle. (2) Pointer Action for Program Operation The pointer action can be done for program operation as follows.
Start Yes
Only 50h area Program? No No
Start address is in 00h area?
Input 50h Command *1
Yes Input 01h Command Input 00h Command *2
Program Sequence
*1: If the read operation was done by setting the start address in 50h within the area in previous use, the 50h command input can be skipped. *2: If the read operation was done at 00h or (and) 01h area during previous use, the 00h command input can be skipped. *3: The read command means 00h, 01h or 50h. No
Continue to Program? Yes
Start address area (00h,01h,50h) is the same as the previous?
No
Start address area is changed from 01h to 00h? No Input read command *3
Yes
Yes 0 255 511 527 The pointer is 01h? No Program Sequence 00h 01h 50h Yes Yes
Set 01h command
Continue to Program? No End
Figure 24 Pointer Action Flow Chart 29
MBM30LV0128
(3) Acceptable commands after serial input command "80h" When the serial input command (80h) is input for program execution, commands other than the program execution command (10h) or reset command (FFh) should not be input.
80 FF
WE R/B
Address input
Figure 25 Reset Command After 80h Input If a command other than "10h" or "FFh" is input, the program operation is not performed.
80 XX 10 In case of this operation, the FFh command is needed.
Other command Programming will not be executed.
(4) Status read during the read operation
00 00 70 [A]
CE WE R/B RE
N address Status read command input Status read Status output
Figure 26 Status Read During Read Operation When the status read command (70h) is input during reading, the next RE clock signal can be input to read the value of the internal status register. Since the internal operation mode is held in Status Read, read data will not be output even if the RE clock signal is input after becoming ready. Status Read is therefore disabled at reading. When the read command (00h) is input during the period [A], the internal operation mode of the device can be canceled, making it possible to read data at address N without inputting Add. (5) Auto program failure
80 Address M 80 Data input 10 M 10 70 Fail I/O 80 Address N Data input 10
If programming at page address (M) fails, data should be programmed at the page address (N) of another block. Data input at first programming at page address (M) will be lost. So address input using the 80h command must follow the same procedure as data input.
N
Figure 27 Auto Program Failure 30
MBM30LV0128
(6) R/B : Termination of the Ready/Busy pin (R/B) The R/B is open-drain output. When using the R/B, R/B must be pulled up VCC by a resistor.
VCC VCC Device CL VSS R R/B
R= =
VCC Max. - VOL IOL + IL 3.2 V 8 mA + IL
Figure 28 Termination for R/B
(7) Power On/Off Sequence : After power-off, each input signal level may be undefined. Use the WP signal as shown in the figure below.
2.7 V 2.5 V VCC
0V
DON'T CARE DON'T CARE VIH VIL Operation VIL
CE, WE, RE CLE, ALE WP
Figure 29 Power On/Off Sequence
31
MBM30LV0128
(8) Setup for WP Signal A Low-level WP signal will force erasing and programming to be reset. To control, use the WP signal as shown below.
Program WE DIN WP R/B
tWW 100 ns (Min.) 80 10
Program Prohibition WE DIN WP R/B
tWW 100 ns (Min.) 80 10
Erase WE DIN WP R/B
tWW 100 ns (Min.) 60 D0
Erase Prohibition WE DIN WP R/B
tWW 100 ns (Min.) 60 D0
32
MBM30LV0128
(9) Address input in 4 cycles The device will get addresses in three cycles. If addresses are input in four cycles, address input in the fourth cycle will be ignored by the chip.
Read operation
CLE CE WE ALE
I/O0 to I/O7
00h, 01h or 50h Address input ignored
R/B
Internal read operation starts when WE in the third cycle goes high.
Figure 30 Read Operation when 4 Address Cycles are Input
Program operation
CLE CE WE ALE
I/O0 to I/O7
80h Address input ignored Data input
Figure 31 Program Operation when 4 Address Cycles are Input
33
MBM30LV0128
(10) Divided programming on same page The device uses a page programming method that allows programming for up to five times on the same page. The procedure for divided programming (programming on a part of one page) is shown below.
The first programming Column A Page N
Column B "No Input" or "1"
Data Pattern 1
The second programming Column C Page N "No Input" or "1" Column D "No Input" or "1"
Data Pattern 2
The third programming Column E Page N "No Input" or "1" Column F Data Pattern 3 "No Input" or "1" Column A Page N Column B Column C Column D Column E "1" Column F "1"
Result Data Pattern 1 Data Pattern 2 Data Pattern 3
"1"
Figure 32 (11) Notification for RE Signal
Divided Program in the Same Page
When the device is in the read mode, the RE signal causes the internal column address counter to increment in synchronization with the RE clock. If the 00h, 01h, or 50h command is input to the device in the read mode, the internal column address counter will count up even after the RE signal is input prior to address input. At this mode, And at input of the RE signal beyond the last column address, the device will start reading (Memory register) even without address input and may output the Busy signal (Sequential Read is started) .
Address input
I/O0 to I/O7
00h/01h /50h
WE RE
R/B
Figure 33
RE Input Before Address
In this way, once the device enters the read mode, unintentional reading may be started after the RE signal is input prior to addressing; therefore, the RE signal should be input after the address input.
34
MBM30LV0128
(12) Invalid block (bad block) The device contains unusable blocks. Therefore, the following issues must be recognized :
Some MBM30LV0128 products have invalid blocks (bad blocks) at shipping. After mounting the device in the system, test whether there are no bad blocks. If there are any bad blocks, they should not be accessed. The bad blocks are connected to sense-amp of the bit lines via the selector transistors. Good blocks will not be affected unless the bad blocks are accessed. The effective number of good blocks specified by Fujitsu is shown below. Min.
Bad Block
Bad Block
Max. 1024
Unit Block
Valid (Good) Block Number
1014
Figure 36. Shows the Bad Block Test Flow
Figure 34 Bad Block (13) Failure Phenomena for Program and Erase Operations Repeated rewriting might cause an error at programming and erasing. Possible error modes, detection methods and remedies are listed in the following table. System-based remedies will provide a highly reliable system. Failure Mode Detection and Countermeasure Sequence Block Page Single Bit* * : (1) or (2) * ECC Erase Failure Program Failure Program Failure "1" "0" Status Read after Erase Block Replacement Status Read after Prog. Block Replacement (1) Block Verify after Prog. Retry (2) ECC
: Error Correcting code Hamming Code etc. Example : 1 bit correction & 2 bit detection. * Block Replacement
Program
error occurs Buffer Memory Block A If an error occurs in block A, reprogramming from the external buffer to block B is recommended. Block A should not be accessed after an error occurs.
Block B
Figure 35 Reprogramming to Good Block Erase If an error occurs at erasing, like programming, remedies should be executed on a system basis to prevent access to blocks causing the error.
35
MBM30LV0128
(14) CE "don't care" timing for read and program operation CE can be "don't-care" ("H" or "L") state during read and program operation as follows.
CE
WE RE I/O0 to I/O7 R/B
(55 ns (Max.)) tCEA Command A0 to A7 A9 to A16 A17 to A23 DOUT N DOUT N+1 DOUT N+2 D DOUT
CE
tREA
RE I/O0 to I/O7 CE
DOUT
tCS
tCH
tWP
WE
CE WE I/O0 to I/O7
80h
A0 to A7
A9 to A16
A17 to A23
DIN 0
DIN 1
DIN 2
DIN *
10h
: VIH or VIL
Note : In the read operation, the CE signal must stay "Low" after the third address input and during Busy state. If the CE signal goes High during this period, the read operation will be terminated and then the standby mode will be entered.
36
MBM30LV0128
s BAD BLOCK TEST FLOW
Test Start
Block No. = 0
Page 0 & 1 Blank Check "All FFh?" Yes Block No. = Block No. + 1 Yes
No
Set as a bad block
B No. < 1023 No
Test End
Figure 36 Bad Block Test Flow
37
MBM30LV0128
s ORDERING INFORMATION
Standard Products Fujitsu standard products are available in several packages. The order number is formed by a combination of : MBM30LV0128 -PFTN
PACKAGE TYPE PFTN = 48-Pin Thin Small Outline Package (TSOP) Standard Pinout PFTR = 48-Pin Thin Small Outline Package (TSOP) Reverse Pinout
DEVICE NUMBER/DESCRIPTION MBM30LV0128 128 Mega-bit (16 M x 8-Bit) CMOS Flash Memory 2.7 V to 3.6 V Read, Write, and Erase
Valid Combinations MBM30LV0128 -PFTN -PFTR
Valid Combinations Valid Combinations list configurations planned to be supported in volume for this device. Consult the local Fujitsu sales office to confirm availability of specific valid combinations and to check on newly released combinations.
38
MBM30LV0128
s PACKAGE DIMENSIONS
48-pin plastic TSOP (II) (FPT-48P-M19)
LEAD No.
1 48
* : Resin protrusion. (Each side : 0.15 (.006) Max)
INDEX
Details of "A" part 0.15(.006) MAX
"A" 0.15(.006)
0.35(.014) MAX 0.25(.010)
24
25
20.000.20 (.787.008) * 18.400.20 (.724.008)
* 12.000.20
(.472.008) 11.50REF (.460) 1.10 -0.05
+0.10 +.004
.043 -.002 (Mounting height)
0.10(.004)
0.50(.0197) TYP 0.150.05 (.006.002) 0.200.10 (.008.004)
0.05(0.02)MIN (STAND OFF) 0.10(.004)
M
19.000.20 (.748.008)
0.500.10 (.020.004)
C
2000 FUJITSU LIMITED F48029S-2C-3
Dimensions in mm (inches)
(Continued)
39
MBM30LV0128
(Continued) 48-pin plastic TSOP (II) (FPT-48P-M20)
LEAD No.
1 48
* : Resin protrusion. (Each side : 0.15 (.006) Max)
INDEX
Details of "A" part 0.15(.006) MAX
"A" 0.15(.006)
0.35(.014) MAX 0.25(.010)
24
25
19.000.20 (.748.008)
0.500.10 (.020.004) 0.150.10 (.006.002) 0.200.10 (.008.004) 0.10(.004)
M
0.10(.004)
0.50(.0197) TYP
0.05(0.02)MIN (STAND OFF)
1.10 -0.05
+0.10 +.004
* 18.400.20
(.724.008) 20.000.20 (.787.008)
11.50(.460)REF
.043 -.002 (Mounting height)
* 12.000.20(.472.008)
C
2000 FUJITSU LIMITED F48030S-2C-3
Dimensions in mm (inches)
40
MBM30LV0128
FUJITSU LIMITED
For further information please contact: Japan FUJITSU LIMITED Corporate Global Business Support Division Electronic Devices Shinjuku Dai-Ichi Seimei Bldg. 7-1, Nishishinjuku 2-chome, Shinjuku-ku, Tokyo 163-0721, Japan Tel: +81-3-5322-3347 Fax: +81-3-5322-3386 http://edevice.fujitsu.com/ North and South America FUJITSU MICROELECTRONICS, INC. 3545 North First Street, San Jose, CA 95134-1804, U.S.A. Tel: +1-408-922-9000 Fax: +1-408-922-9179 Customer Response Center Mon. - Fri.: 7 am - 5 pm (PST) Tel: +1-800-866-8608 Fax: +1-408-922-9179 http://www.fujitsumicro.com/ Europe FUJITSU MICROELECTRONICS EUROPE GmbH Am Siebenstein 6-10, D-63303 Dreieich-Buchschlag, Germany Tel: +49-6103-690-0 Fax: +49-6103-690-122 http://www.fujitsu-fme.com/ Asia Pacific FUJITSU MICROELECTRONICS ASIA PTE. LTD. #05-08, 151 Lorong Chuan, New Tech Park, Singapore 556741 Tel: +65-281-0770 Fax: +65-281-0220 http://www.fmap.com.sg/ Korea FUJITSU MICROELECTRONICS KOREA LTD. 1702 KOSMO TOWER, 1002 Daechi-Dong, Kangnam-Gu,Seoul 135-280 Korea Tel: +82-2-3484-7100 Fax: +82-2-3484-7111
All Rights Reserved. The contents of this document are subject to change without notice. Customers are advised to consult with FUJITSU sales representatives before ordering. The information and circuit diagrams in this document are presented as examples of semiconductor device applications, and are not intended to be incorporated in devices for actual use. Also, FUJITSU is unable to assume responsibility for infringement of any patent rights or other rights of third parties arising from the use of this information or circuit diagrams. The contents of this document may not be reproduced or copied without the permission of FUJITSU LIMITED. FUJITSU semiconductor devices are intended for use in standard applications (computers, office automation and other office equipments, industrial, communications, and measurement equipments, personal or household devices, etc.). CAUTION: Customers considering the use of our products in special applications where failure or abnormal operation may directly affect human lives or cause physical injury or property damage, or where extremely high levels of reliability are demanded (such as aerospace systems, atomic energy controls, sea floor repeaters, vehicle operating controls, medical devices for life support, etc.) are requested to consult with FUJITSU sales representatives before such use. The company will not be responsible for damages arising from such use without prior approval. Any semiconductor devices have inherently a certain rate of failure. You must protect against injury, damage or loss from such failures by incorporating safety design measures into your facility and equipment such as redundancy, fire protection, and prevention of over-current levels and other abnormal operating conditions. If any products described in this document represent goods or technologies subject to certain restrictions on export under the Foreign Exchange and Foreign Trade Control Law of Japan, the prior authorization by Japanese government should be required for export of those products from Japan.
F0101 (c) FUJITSU LIMITED Printed in Japan


▲Up To Search▲   

 
Price & Availability of MBM30LV0128-PFTR

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X